Search

In Stock

VentStar – Small Animal Ventilator

R415 VentStar Small Animal Ventilator was designed for animal research applications and is widely using on subjects ranging in size from mice to guinea pigs. The ventilator provides to maintain versatility and ease of use while fostering safe and physiologically accurate mechanical ventilation conditions.

1.Suitable for mice to guinea pigs range 10 g to 1 kg
2. Convenient for the setting of animal ventilator data by inputting animal weight
3. Built-in VCV and PIPCV working modes
4. Real-time graphical display of tracheal pressure
5. Touch Screen with a 75-degree visual surface design for easy operation
Suggested Weight Range
10g~1kg
Species
Mouse/Rat~Guinea Pig
Tidal Volume Range (TV)
0.05ml~5ml    Resolution: 0.001ml
Peak Inspiratory Pressure (PIP)
1~50cmH2O    Resolution: 1 cmH2O
Accuracy: ±0.7 cmH2O
PEEP
0~10 cmH2O   Resolution: 1 cmH2O
Breath Rate (bpm)
10~300 bpm
I:E Ratio
20~80%
Sigh Breath
Frequency: Every 10~999 or Manual
Volume: 0~20% of tidal volume (in volume mode) or PIP (in pressure volume)
Display
7’’ LCD touchscreen, resistive
Remote Communication
RS-485
Power Supply
100~240VAC, 50/60Hz
Input Power
24V DC,   adaptor: 40W Max
Safety Alarms
Over-/Under-pressure, occlusion, high PEEP
Dimensions
320*210*180mm
Weight
5.1kg
Operating Temperature
4℃~40℃ (40°F~104°F)
Operating Humidity
20~80%, non-condensing
Storage Temperature & Humidity
-10℃~70℃ (14°F~158°F), 20%~80% RH, non-condensing
Cat No.
Product Description
R415
 Small Animal Ventilator
R415-AP
Accessory package for Anesthesia and Ventilator

Bestsellers

Cage-Level Filter Testing

Cage-level filter testing is a valuable tool to include in your health-monitoring program.

Photoperiod Zebra Fish Housing System

PVC-fabricated main structure, corrosion-resistant Electric roller blinds ( able to control roller blinds up / down to stop at any position ). Fluorescent lamps operate in coordination with the electric roller blinds to proceed the photoeriod experiment and accelerate the incubation. Able to control the on / off and timer function of fluorescent lamp layer by layer. Integrated the mechanical, biological and chemical filtration systems as a whole. Gravitational flow filtration system for energy saving. Optional devices: pH meter, flow meter, DO ( dissolved oxygen ) meter, conductivity meter. Custom-made system is available.

Anesthesia Induction Chambers

Anesthesia induction chambers are applied to inhalation anesthesia. For rapid induction of anesthesia before animal surgery, takes only 2-5 minutes; Animal status can be observed in real time during anesthesia

VentStar - Small Animal Ventilator

R415 VentStar Small Animal Ventilator was designed for animal research applications and is widely using on subjects ranging in size from mice to guinea pigs. The ventilator provides to maintain versatility and ease of use while fostering safe and physiologically accurate mechanical ventilation conditions.

Rodent Manual Non-Invasive Blood Pressure System

The manual Rodent Non-Invasive Blood Pressure System, uses the tail cuff method to measure Blood pressure in rodents.  This is similar to to way blood pressure is measured in humans.  Instead of using a human arm we will be using the tail of the rodent.

Rotarod Test Rats and Mice

The IITC Rotarod Test is used to assess the effect of drugs on the motor coordination or fatigue resistance on mice and rats using one unit in a safe and humane way.

Stereotaxic Animal Anesthesia Solutions

This solution is specially used for neuroscience research. Unique stereotaxic frame nosecone masks are designed to combine anesthesia system and stereotaxic location system, which makes brain-related procedures or research more successful and have much better outcomes, for example, development of animal neurological diseases models (Alzheimer’s and Parkinson’s diseases, cerebral and spinal cord injury etc.), drug injection to brain, cannula implantation for long-term drug administration, nervous stimulation, physiological signal record, microdialysis probe implantation and so on. Similarly, any leaks around animal’s nose can be captured by the scavenging system to protect research subjects from being exposed

Back to Top
Product has been added to your cart